In some instances starting VICO Office on 64 bit system could be a bit problematic during an active VPN session or immediately followed closing of such. In order to jump start VICO Office, VERSANT database service needs to be restarted. Simply open your Computer management panel and under listed services look for "VERSANTD", select it and restart it.
This will take care of your post VPN blank VICO Office dashboard .
Tuesday, September 14, 2010
Tuesday, January 26, 2010
Revit Categories....
While mapping our assembly classification from Uniformat II to OmniClass Table 21 I needed the list of Revit object categories. This is only a part of that 200+ entry list that can be accessed upon exporting Revit model to ODBC.
| Id | Name |
| -2000011 | Walls |
| -2000014 | Windows |
| -2000023 | Doors |
| -2000032 | Floors |
| -2000035 | Roofs |
| -2000038 | Ceilings |
| -2000080 | Furniture |
| -2000100 | Columns |
| -2000120 | Stairs |
| -2000126 | Railings |
| -2000151 | Generic Models |
| -2000160 | Rooms |
| -2000170 | Curtain Panels |
| -2000171 | Curtain Wall Mullions |
| -2000180 | Ramps |
| -2000190 | Filled region |
| -2000191 | Plan Region |
| -2000340 | Curtain Systems |
| -2000700 | Materials |
| -2000996 | Shaft Openings |
| -2001000 | Casework |
| -2001040 | Electrical Equipment |
| -2001060 | Electrical Fixtures |
| -2001100 | Furniture Systems |
| -2001120 | Lighting Fixtures |
| -2001140 | Mechanical Equipment |
| -2001160 | Plumbing Fixtures |
| -2001180 | Parking |
| -2001220 | Roads |
| -2001260 | Site |
| -2001300 | Structural Foundations |
| -2001320 | Structural Framing |
| -2001327 | Structural Beam Systems |
| -2001330 | Structural Columns |
| -2001336 | Structural Trusses |
| -2001340 | Topography |
| -2001350 | Specialty Equipment |
| -2001354 | Structural Stiffeners |
| -2001360 | Planting |
| -2001370 | Entourage |
| -2003600 | Spaces |
| -2008000 | Ducts |
| -2008003 | Duct Tags |
| -2008010 | Duct Fittings |
| -2008013 | Air Terminals |
| -2008015 | Duct Systems |
| -2008016 | Duct Accessories |
| -2008020 | Flex Ducts |
| -2008037 | Electrical Circuits |
| -2008039 | Wires |
| -2008043 | Piping Systems |
| -2008044 | Pipes |
| -2008049 | Pipe Fittings |
| -2008050 | Flex Pipes |
| -2008055 | Pipe Accessories |
| -2008075 | Telephone Devices |
| -2008077 | Nurse Call Devices |
| -2008078 | Nurse Call Device Tags |
| -2008079 | Security Devices |
| -2008081 | Communication Devices |
| -2008083 | Data Devices |
| -2008085 | Fire Alarm Devices |
| -2008087 | Lighting Devices |
| -2008090 | gbXML Surface |
| -2008099 | Sprinklers |
| -2008101 | Switch System |
| -2008107 | HVAC Zones |
| -2009000 | Structural Rebar |
| -2009003 | Structural Area Reinforcement |
| -2009009 | Structural Path Reinforcement |
| -2009010 | Structural Path Reinforcement Symbols |
| -2009013 | Rebar Shape |
| -2009030 | Structural Connections |
Thursday, January 21, 2010
Top Ten reasons to do 5D BIM
Interesting perspective on why to use cost estimating as well schedule integration as a part of the comprehensive Virtual Design and Construction process...
Wednesday, January 06, 2010
Head-Tracking VR technology for BIM models
An interesting application of head-tracking technology which can be used to examine 3D models.
Monday, November 30, 2009
Design Computation Symposium
AU had a great start with the symposium that addressed several direction in development of computational design. Informative sessions by the leaders in the advanced use of computation tools shed some light on the future of digital media its role within anthropocentric reality.
Notable lecture were given by prof. Dr. Kristina Shea on integration of knowledge management and generative design and fabrication, Jos Stam on Unified Dynamic Solver used in CG apps to simulate physical effects in a dynamic systems and Prof. Joe Clark of University of Strathclyde on Building Performance Simulation and the need for a unified model approach required for the whole building energy analysis.
Notable lecture were given by prof. Dr. Kristina Shea on integration of knowledge management and generative design and fabrication, Jos Stam on Unified Dynamic Solver used in CG apps to simulate physical effects in a dynamic systems and Prof. Joe Clark of University of Strathclyde on Building Performance Simulation and the need for a unified model approach required for the whole building energy analysis.
AU Building Performance Analysis
This year's AU attention to sustainable design with the aid of Autodesk's BIM enabled applications is just another confirmation that ADSK means green business. I am particularly interested to see how far down the road we can push the information gathered through sustainability analysis during the design process into the construction activities. Some courses look very promising in that regard.
Along the same lines they just ‘up the ante’ by conducting the survey of their existing facilities from the energy footprint point of view. These results are published and posted on Autodesk’s website (Link).
Along the same lines they just ‘up the ante’ by conducting the survey of their existing facilities from the energy footprint point of view. These results are published and posted on Autodesk’s website (Link).
Sunday, November 15, 2009
Post Occupany Energy Use Analysis
Case study in usability of Ecotect Analysis for the adaptive reuse projects. More information on this project is available upon a request.